? S68000 bus compatible
? Dual full-duplex asynchronous receiver/transmitter
? Quadruple buffered receiver data registers
? Programmable data format
?5 to 8 data bits plus parity
?Odd, even, no parity or force parity
?1, 1.5 or 2 stop bits programmable in 1/16-bit increments
? Programmable baud rate for each receiver and transmitter
selectable from:
? 22 fixed rates: 50 to 115.2k baud
? Non-standard rates to 115.2kb
? Non-standard user-defined rate derived from programmable
counter/timer
? External 1X or 16X clock
? 16-bit programmable Counter/Timer
? Parity, framing, and overrun error detection
? False start bit detection
? Line break detection and generation
? Programmable channel mode
? Normal (full-duplex)
? Automatic echo
? Local loopback
? Remote loopback
? Multi-function programmable 16-bit counter/timer
? Multi-function 6-bit input port
? Can serve as clock or control inputs
? Change-of-state detection on four inputs
? 100kΩ typical pull-up resistors
? Multi-function 8-bit output port
? Individual bit set/reset capability
? Outputs can be programmed to be status/interrupt signals
For more information, please visit this products data sheet. |
|